Functional Principle: Moisture gas passes through the inlet separator, where liquid hydrocarbons and solid impurities are removed, before entering the bottom of the absorption tower. Inside the absorption tower, it passes upward through a packing section filled with glycol, where it fully contacts the glycol and absorbs moisture, becoming a glycol-rich liquid. This glycol-rich liquid then passes through a triethylene glycol regeneration skid in a heat exchanger and reboiler, becoming lean triethylene glycol, before returning to the top of the absorption tower. The entire system is reusable.
Components: Mainly composed of an absorption tower, a lean-rich heat exchanger, a triethylene glycol regeneration skid, and a triethylene glycol storage tank, along with valves, instruments, and an automatic control system.
Series of products:
Processing capacity: 150 x 10⁴ m³/d, 200 x 10⁴ m³/d
330x10⁴ m³/d, Working pressure: Atmospheric pressure ~ 2.5 MPa. [Image of image: src="/static/upload/image/20251128/2025112812001332.png" title="2025112812001332.png" alt="image.png"]